Electrical Resistance Tester

Electrical resistance is of a great importance in case of conductive and anti-static footwear. The electrical resistance of footwear is measured at a specified voltage applied between a copper contact plate on which the footwear is placed and steel balls kept in the footwear
 
BS EN 344 - 1992
 
Requirement and Test Methods for Safety, Protective, and Occupational Footwear for Professional Use
 
Clauses 4.3.4 and 5.7
 
Electrical Resistance
 
 
Technical Details
 
Test voltage
 
100 ± 2 volts DC
 
Internal electrodes
 
4 mm diameter steel balls (total mass 4 kg)
 
External electrode
 
100 mm x 230 mm x 6 mm thick copper plate
 
Voltmeter (make AE)
 
199.9 volts DC (digital)
 
Ammeter (make AE)
 
A (digital)mA, and 19.99 m199.9 mA, 1999